首页   按字顺浏览 期刊浏览 卷期浏览 SIMULTANEOUS HPLC ANALYSIS OF PALM CAROTENOIDS AND TOCOPHEROLS USING A C-30 COLUMN AND ...
SIMULTANEOUS HPLC ANALYSIS OF PALM CAROTENOIDS AND TOCOPHEROLS USING A C-30 COLUMN AND PHOTODIODE ARRAY DETECTOR

 

作者: D. Darnoko,   M. Cheryan,   E. Moros,   J. Jerrel,   E.G. Perkins,  

 

期刊: Journal of Liquid Chromatography & Related Technologies  (Taylor Available online 2000)
卷期: Volume 23, issue 12  

页码: 1873-1885

 

ISSN:1082-6076

 

年代: 2000

 

DOI:10.1081/JLC-100100459

 

出版商: Taylor & Francis Group

 

数据来源: Taylor

 

摘要:

An HPLC method for simultaneous identification and quantitation of tocopherols and carotenoids in red palm oil was developed. A C-30 column was used in a HPLC equipped with a photodiode detector and with methyl tertiary-butyl ether/methanol/water as the mobile phase. Tocopherols and carotenoids were monitored at 295 nm and 450 nm, respectively. Gradient elution resulted in complete separation of five tocopherols such as α-, δ-, γ-tocopherols and tocotrienols in palm oil in less than 10 minutes. Several (13) carotenoids were also detected and quantitated in red palm oil within 45 minutes.

 

点击下载:  PDF (342KB)



返 回