首页   按字顺浏览 期刊浏览 卷期浏览 Moments Method Calculation of Buildup Factors for Point Isotropic Monoenergetic Gamma-R...
Moments Method Calculation of Buildup Factors for Point Isotropic Monoenergetic Gamma-Ray Sources at Depths Greater than 20 Mean-Free-Paths

 

作者: MorrisE. E.,  

 

期刊: Nuclear Science and Engineering  (Taylor Available online 1973)
卷期: Volume 50, issue 1  

页码: 32-37

 

ISSN:0029-5639

 

年代: 1973

 

DOI:10.13182/NSE73-A22585

 

出版商: Taylor&Francis

 

数据来源: Taylor

 

摘要:

A method of extending moments method calculations for monoenergetic, point isotropic gamma ray sources to depths of approximately 50 mean-free-paths is described. Sample calculations are given for water and aluminum. A method of error analysis recently developed by Spencer suggests that for the range from 10 to∼50 mean-free-paths, the errors associated with the reconstruction of the flux from moments are generally<1%. Comparisons are made between the asymptotic, deep penetration trend of the calculated results and the trend predicted by a theory developed by Fano.

 

点击下载:  PDF (453KB)



返 回