Precision Measurement of the Half‐Life of56Co
作者:
D. E. Alburger,
C. Wesselborg,
期刊:
AIP Conference Proceedings
(AIP Available online 1991)
卷期:
Volume 238,
issue 1
页码: 911-913
ISSN:0094-243X
年代: 1991
DOI:10.1063/1.41177
出版商: AIP
数据来源: AIP
摘要:
Gamma rays from a mixed source of56Co+46Sc were measured in a Ge(Li) detector. The56Co/46Sc intensity ratios I847/I889were determined by careful analysis of line shapes and underlying backgrounds. Based on the known46Sc adopted half‐life value of 83.810(10) d, the fit to the intensity ratios corrected for46Sc decay from 107 runs over an elapsed time of 172 days gave a half‐life of 77.29(3) d. By combining this result with other published data we obtain a half‐life of t1/2=77.27(3) d for56Co.