Effective Radium Content in Egyptian Soil by CR-39 and LR-115 Plastic Nuclear Track Detectors
作者:
A. F. Hafez,
B. M. Moharram,
A. M. El-Khatib,
A. Abdel-Naby,
期刊:
Isotopenpraxis Isotopes in Environmental and Health Studies
(Taylor Available online 1991)
卷期:
Volume 27,
issue 4
页码: 185-188
ISSN:0021-1915
年代: 1991
DOI:10.1080/10256019108622504
出版商: Taylor & Francis Group
关键词: dielectric track detectors;diffusion;diffusion length;etching;particle tracks;porosity;radioactivity;radon 226;soils
数据来源: Taylor
摘要:
CR-39 and LR-115 plastic detectors were used in air volume of several sealed cylinderical plastic tubes (can-technique) for time integrated long term measurement of radon activity concentrations. Dried soil samples, collected from the Egyptian Nile delta, were used. The tubes, 3.8 cm inner diameter and 20–170 cm in heights, were filled at the bottom with the dry soil samples up to different thicknesses (10–160 cm). The registeration sensitivities of CR-39 and LR-115 nuclear plastic detectors in the sealed tube, taking into consideration the plated-out activity on the walls, are discussed. The porosity of the soil samples, the diffusion length, the effective and real radium-226 contents were estimated. The results showed that the sealed tube technique could be used as a useful tool for the measurement of the radium concentration with reasonable accuracy.
点击下载:
PDF (321KB)