Development of Small Twin-Valveless Pulse Combustors: Effect of Injection System
作者:
ICHIRO HONGO,
KAZUO SAITO,
期刊:
Combustion Science and Technology
(Taylor Available online 1993)
卷期:
Volume 94,
issue 1-6
页码: 43-55
ISSN:0010-2202
年代: 1993
DOI:10.1080/00102209308935303
出版商: Taylor & Francis Group
关键词: Twin-Valveless Pulse combustor;NOx;Thermal Efficiency
数据来源: Taylor
摘要:
The performance of gas-fired residential sized twin pulse combustors with two aerodynamic valves for residential heating appliances is discussed. Two injection system are tested. Pre-mixed injection resulted in having better stability of anti-phase operating mode between the two combustion chambers which reduced the noise level less than 50 dB(A). The combustor shows NOxemissions of 25 ppm and a thermal efficiency of 93% over a wide turndown from 1,100 to 6,000 W. At a lower heat input region, the combustor can still operate in the anti-phase mode with fuel supply to only one combustor. It is shown that twin-valveless pulse combustors have the potential for compactness, low noise, and efficient operation over a wide turn down ratio for residential use.