首页   按字顺浏览 期刊浏览 卷期浏览 Particle Size Determination by Laser Reflection: Methodology and problems
Particle Size Determination by Laser Reflection: Methodology and problems

 

作者: Olivier Monnier,   Jean‐Paul Klein,   Berthe Ratsimba,   Christian Hoff,  

 

期刊: Particle&Particle Systems Characterization  (WILEY Available online 1996)
卷期: Volume 13, issue 1  

页码: 10-17

 

ISSN:0934-0866

 

年代: 1996

 

DOI:10.1002/ppsc.19960130104

 

出版商: WILEY‐VCH Verlag GmbH

 

数据来源: WILEY

 

摘要:

AbstractThe particle size distribution of crystalline solids has progressively become a key parameter in manufacturing processes, as important as chemical purity. Among the particle size determination and counting systems available on the market, very few offer the possibility of continuous in situ monitoring of the particle size evolution during crystallization. For this reason, much interest has been aroused by the appearance of the Par Tec 100, patented by Laser Sensor Technology [1, 2]. A study has been carried out in a stirred vessel to verify the precision and reproducibility of particle size measurement and elucidate the influence of experimental parameters on data accessible with this instrument. Optimum reproducibility has logically been achieved by fixing the highest possible cycle time and taking the mean of several cycles. Determinations with the Par Tec 100 are influenced variously, according to whether they relate to the total number of particles counted or to the mean size. Thus, the number of counts measured by a particle size probe largely depends on the operating conditions and more particularly on the hydrodynamic conditions, solvent, temperature and focal point position. Its dependence relative to the concentration of the solid in suspension is normal and linear for a solid and for a given monodisperse sample. To establish the relationship between the number of counts and the population density would therefore necessitate delicate calibration on a case‐by‐case basis. The mean size determined does not depend on suspension homogeneity, provided that the stirring speed is sufficient for a statistically significant total count. On the other hand, for a given sample, a displacement of the focal point can lead to considerable variations in the size determined. The optimal focal point position for small sizes is in fact highly sensitive. Lastly, the optimal position of the focal point is considerably dependent on the true size of the particles, which means that this counter is unsuitable for the precise analysis of a dispersed sample since each particle size class would require a different setting of the focal point. In addition, the sizes determined, irrespective of the products studied, appear to be underestimated for large particles and over estimated for small partic

 

点击下载:  PDF (825KB)



返 回