The Design and Application of a Packed Column Ozone Absorber in Water Reclamation
作者:
J. van Leeuwen,
期刊:
Ozone: Science & Engineering
(Taylor Available online 1980)
卷期:
Volume 2,
issue 3
页码: 283-298
ISSN:0191-9512
年代: 1980
DOI:10.1080/01919518008550889
出版商: Taylor & Francis Group
关键词: Ozonation;water reclamation;mass transfer;packed column
数据来源: Taylor
摘要:
A packed column for the absorption of ozone from ozonated air to further purify chemically clarified, biologically treated sewage, gave excellent results after fitting gas redistributor plates. Ozone utilization exceeded 85 % and the total losses over the unit process amounted to less than 5 % when an injector recontacting system was also incorporated into the calculation. Ozonation prior to active carbon treatment prolonged the operational life of the material considerably, probably through improved biological activity. Ozone could not entirely replace chlorine as a disinfectant.