Comparison of Tc-99m HMPAO Fast SPECT with Tc-99m HMPAO Conventional SPECT in Patients with Acute Stroke

 

作者: MOTOO OSHIMA,   MASANORI TADOKORO,   SADAYUKI SAKUMA,  

 

期刊: Clinical Nuclear Medicine  (OVID Available online 1992)
卷期: Volume 17, issue 1  

页码: 18-22

 

ISSN:0363-9762

 

年代: 1992

 

出版商: OVID

 

数据来源: OVID

 

摘要:

Tc-99m HMPAO SPECT is more likely to detect a stroke in early stages than CT. However, a conventional HMPAO SPECT study takes at least 30 minutes to complete. This paper compares fast Tc-99m HMPAO SPECT scans and conventional Tc-99m HMPAO SPECT scans with respect to spatial resolution and diagnostic efficacy in vitro and in a small series of patients, respectively. The spatial resolution of fast Tc-99m HMPAO SPECT did not match that of images obtained from conventional SPECT, though the difference proved to be of no clinical significance. Since fast SPECT requires only one-fourth to one-fifth the time necessary for conventional SPECT, it may be more suitable for investigating cases of acute stroke in critical clinical situations.

 