首页   按字顺浏览 期刊浏览 卷期浏览 A comparative study of the clinical efficacy of Screw Vent irnnlants versus Brånemark f...
A comparative study of the clinical efficacy of Screw Vent irnnlants versus Brånemark fixtures, installed in a periodontal clinic

 

作者: H. De Bruyn,   B. Collaert,   U. Lindh,   L. Flygare,  

 

期刊: Clinical Oral Implants Research  (WILEY Available online 1992)
卷期: Volume 3, issue 1  

页码: 32-41

 

ISSN:0905-7161

 

年代: 1992

 

DOI:10.1034/j.1600-0501.1992.030106.x

 

出版商: Munksgaard International Publishers

 

关键词: dental implants;osseointegration;titanium;marginal bone loss

 

数据来源: WILEY

 

摘要:

The clinical success of 85 Screw Vent® and 107 Bråemark® implants, consecutively installed in a private periodontal clinic under the same conditions and by the same operator, is compared. Mobile implants were removed and considered as failures. Intraoral radiographs were assessed for the presence of peri‐implant radiolucencies and for analysis of bone loss after functional loading. 85 Screw Vent implants were installed in 31 patients. Of 23 implants installed in 9 mandibles, none failed after 16.8 (range 12–25) months of function. Of 62 Screw Vent implants installed in 23 maxillae, 6 failed at abutment connection, 1 failed after 2 months and 2 after 13 months of function. The absolute failure rate after 13.2 (range 6–24) months was 9162. Mean loss of bone was 1.47 mm (‐l.O–+4) after 12 months of functional loading. 107 Brånemark fixtures were installed in 25 patients. Of 51 fixtures inserted in 12 mandibles, none failed; of 56 fixtures installed in 13 maxillae 1 failed before and 2 failed during abutment connection. The absolute failure is 3156. All remaining fixtures were immobile after loading. 13 fixtures were more than 6 months in function. Only short‐term comparison between both systems is possible because the observation time is longer for the Screw Vent implants. In the 1st year, only 1 implant system was available to the periodontist. Short‐term comparison reveals 11.3% versus 5.3% of cumulative failure after 6 months for the Screw Vent and Brånemark implants, respectively. The results indicate that clinical efficacy is as effectively obtained with Screw Vent as with Brånemark implants in the mandible. The outcome of treatment with Screw Vent implants in the maxilla see

 

点击下载:  PDF (1909KB)



返 回