首页   按字顺浏览 期刊浏览 卷期浏览 Are intersecting staple lines a hazard in intestinal anastomosis?
Are intersecting staple lines a hazard in intestinal anastomosis?

 

作者: Thomas Zilling,   Bruno Walther,  

 

期刊: Diseases of the Colon & Rectum  (OVID Available online 1992)
卷期: Volume 35, issue 9  

页码: 892-896

 

ISSN:0012-3706

 

年代: 1992

 

出版商: OVID

 

关键词: Small bowel anastomosis;Colonic anastomosis;Stapling devices;Microcirculation

 

数据来源: OVID

 

摘要:

&NA;To determine the safety of intersecting staple lines, 22 pigs were operated upon with a functional end‐to‐end enteroanastomosis 40 cm distal to the ligament of Treitz using linear stapling devices. The procedure was repeated on the colon, where a colocolostomy was created. The blood flow at intersecting staple lines and single‐row staple lines for each anastomosis was studied with the reference organ method 24 hours after the first operation. The purpose was to evaluate whether there is a reduction in blood flow at the site of intersecting staple lines, causing an increased risk for anastomotic leakage. The reduction in mean blood flow in crossing compared with noncrossing staple lines was 6 percent (−5‐17 percent) for small bowel anastomoses and 7 percent (−6‐19 percent) for colonic anastomoses. An equivalence test showed that, if a reduction in blood flow exists between crossing and noncrossing staple lines, it is most likely less than 30 percent(P<0.001) for both small bowel and colonic anastomoses. This experimental study demonstrates that intersecting staple lines in small bowel and colonic anastomoses do not reduce anastomotic blood flow to a dangerous level.

 

点击下载:  PDF (476KB)



返 回