首页   按字顺浏览 期刊浏览 卷期浏览 Determination of Metals in a Small Volume of Reference Serum by Automatically Triggered...
Determination of Metals in a Small Volume of Reference Serum by Automatically Triggered Digital Integrator-Flame Atomic Absorption and Emission Spectrometry with Discrete Nebulization

 

作者: I. Kojima,   C. Iida,  

 

期刊: Analytical Letters  (Taylor Available online 1982)
卷期: Volume 15, issue 6  

页码: 543-548

 

ISSN:0003-2719

 

年代: 1982

 

DOI:10.1080/00032718208064398

 

出版商: Taylor & Francis Group

 

关键词: Small volume sample;Reference serum;Copper;calcium;magnesium;sodium and potassium;Atomic absorption and emission spectrometry;Discrete nebulization

 

数据来源: Taylor

 

摘要:

The amount of copper, calcium, magnesium, sodium and potassium in reference serum were determined by integration of the signal. About 100 μ1 of the serum was diluted to 5 ml. Each 100 μ1 of this sample solution and standard solution was used for the determination. The results agreed well with the difinitive or recommended values.

 