Detection of arsenosugars from kelp extractsviaIC-electrospray ionization-MS-MS and IC membrane hydride generation ICP-MS

 

作者: Patricia A. Gallagher,  

 

期刊: Journal of Analytical Atomic Spectrometry  (RSC Available online 1999)
卷期: Volume 14, issue 12  

页码: 1829-1834

 

ISSN:0267-9477

 

年代: 1999

 

DOI:10.1039/a906249a

 

出版商: RSC

 

数据来源: RSC

 

摘要:

Detection of arsenosugars from kelp extracts via IC-electrospray ionization-MS-MS and IC membrane hydride generation ICP-MS{ Patricia A. Gallagher, Xinyi Wei,{ Jody A. Shoemaker, Carol A. Brockhoff and John T. Creed* US EPA NERL Microbiological and Chemical Exposure Assessment Research Division, Cincinnati, OH 45268, USA Received 2nd August 1999, Accepted 21st September 1999 The selectivity and the ability to obtain structural information from detection schemes used in arsenic speciation research are growing analytical requirements driven by the growing number of arsenicals extracted from natural products and the need to minimize misidentiÆcation in exposure assessments.Three arsenosugars were extracted from ribbon kelp utilizing accelerated solvent extraction. The three arsenosugars were separated from other arsenicals with near baseline resolution using a PRP-X100 column and a 20 mM (NH4)2CO3 mobile phase at a pH of 9 with IC-ICP-MS detection. Utilizing these chromatographic conditions, the molecular weight was determined for each arsenosugar utilizing ion chromatography-electrospray ionization-mass spectrometry (IC-ESI-MS) in the positive ion mode. The molecular weight and retention times for the three arsenicals are 328 u (4.6 min), 482 u (8.2 min) and 392 u (14.2 min).The IC-ESI-MS-MS spectra from each of the arsenosugars were compared to the spectra reported in the literature, which were obtained via direct infusion of standard materials.All three MS-MS spectra contain m/z 237, 195 and 97, which are fragments of the base dimethylarsinylriboside common to all the arsenosugars. Adequate sensitivity for each arsenical was achieved using a 6.1 ng and a 22 ng injection for IC-ESI-MS and IC-ESI-MS-MS, respectively. Given the unavailability of standards, the arsenosugar distribution was determined via relative chromatographic areas using IC-ICP-MS. The IC-ICP-MS indicated the presence of an arsenic heteroatom within the same retention windows in which the arsenosugars were detected via IC-ESI-MS. The IC-ESI-MS and IC-ESI-MS-MS detection scheme provided structural information but at reduced sensitivity.In an attempt to preserve sensitivity and improve selectivity of the IC-ICP-MS, an on-line membrane hydride generation detection scheme was evaluated. The hydride system indicated that the three unknown peaks (arsenosugars) were not hydride active, thereby simplifying the chromatographic resolution needed to quantitate the more toxicologically important arsenicals, such as MMA, DMA, As(III) and As(V), while minimizing the potential for misidentiÆcation.Introduction The two major pathways for arsenic exposure are drinking water and dietary intake. The geographical distribution of arsenic in surface water and ground water in the US has been estimated by Frey and Edwards.1 Inorganic arsenic is the predominant species present in drinking water and it is estimated that approximately 15% of the US population is exposed to arsenic in drinking water at concentrations greater than 2 mg L21.Dietary exposure to total arsenic (arsenic determined after acid digestion) has been estimated.2±4 The naturally occurring and anthropogenic arsenicals are assimilated into many foods with the highest concentrations being found in Æsh and shellÆsh. Unlike water, the dietary sources of arsenic contain a variety of arsenicals.5±14 Some of these arsenicals are thought to be carcinogenic, others are thought to be cancer promoters, while some are considered non-toxic.This species-dependent toxicity of arsenicals requires analytical techniques capable of distinguishing the toxic from the nontoxic chemical forms. Therefore, an accurate risk assessment which incorporates the two major sources of arsenic exposure must estimate the toxic and non-toxic species found in the dietary components. One essential aspect of an accurate risk assessment for arsenic is sensitive and selective analytical methods capable of speciating arsenic in a variety of exposure assessment matrices.The analytical capability to speciate arsenic in a wide variety of sample matrices is a rapidly growing research area. Analytical capability to speciate arsenic has been demonstrated in environmental matrices,15±19 biologicals20±32 and dietary samples5±14,33±36. Much of this research has focused on the use of atomic spectroscopy and more recently ICP-MS as the detector of choice because of the inherent sensitivity and elemental selectivity.The ability to obtain structural information from detection schemes used in arsenic speciation research is a growing analytical requirement driven by the growing number of arsenicals extracted from natural products and the need to minimize misidentiÆcation in exposure assessments. This growing list produces the potential for false positives based on insufÆcient chromatographic resolution or detector selectivity.Improved chromatographic resolution via capillary electrophoresis is an active area of research within arsenic speciation.37,38 Alternatively, the use of electrospray ionization (ESI) mass spectrometry as a detector for LC can provide structural information39,40 on eluting arsenicals and, in turn, improve detector selectivity.41±43 This structural information is obtained at the cost of reduced sensitivity relative to ICP-MS. A third approach to minimizing misidentiÆcation is to capitalize on the inability of highly derivatized arsenicals to produce a volatile hydride.44,45 This in effect improves the selectivity of atomic spectroscopy based detection systems while preserving the required sensitivity.This paper will report on the use of {US Government Copyright. {National Research Council Postdoctoral Fellow. J. Anal. At. Spectrom., 1999, 14, 1829±1834 1829 This journal is # The Royal Society of Chemistry 1999IC-ESI-MS-MS and IC hydride generation ICP-MS as a means of improving detector selectivity relative to conventional atomic spectroscopy.The IC-ESI-MS-MS system will be used to characterize three arsenosugars as they elute from a conventional anion exchange column while IC hydride generation ICP-MS will be used to preserve sensitivity and demonstrate an added degree of selectivity. Experimental Reagents The ribbon kelp (Alaria marginata) was received from Puget Sound, WA, USA.The HPLC grade methanol (MeOH) and trace metal grade ammonium hydroxide (NH4OH) originated from Fisher ScientiÆc (Pittsburgh, PA, USA). The ACS reagent grade ammonium carbonate [(NH4)2CO3] was purchased from Aldrich (Milwaukee, WI, USA) while the ammonium phosphate [(NH4)2HPO4] and the ultrapure reagent grade nitric acid (HNO3) were from J. T. Baker (Phillipsburg, NJ, USA). For hydride generation, trace metal grade HCl (Fisher, Pittsburgh, PA, USA) was used, and NaBH4 (97z%, Alfa AESAR, Johnson Matthey, Ward Hill, MA, USA) was prepared in 0.1 M NaOH (97z%, certiÆed ACS; Fisher, Fair Lawn, NJ, USA) solution for stabilization.K2S2O8 (99z%, ACS reagent) was purchased from Aldrich. The water used was always 18MV by Millipore (Bedford, MA, USA). The arsenite [As(III)] and arsenate [As(V)] were purchased from Spex CertiPrep (Metuchen, NJ, USA). Dimethylarsinic acid (DMA) and disodium methylarsenate (MMA) were from Chem Services (West Chester, PA, USA).Arsenobetaine (AsB) was from University of British Columbia, Department of Chemistry (Vancouver, Canada). All standard materials were prepared based on arsenic and standardized against NIST 1643c obtained from the US Department of Commerce National Institute of Standards and Technology (Gaithersburg, MD, USA). Sample preparation±accelerated solvent extraction The ribbon kelp was freeze dried utilizing a VirTis lyophilizer (Gardiner, NY, USA) followed by homogenization in an Osterizer blender (Milwaukee, WI, USA).The ribbon kelp samples were extracted using an ASE 200 accelerated solvent extractor system (Dionex, Sunnyvale, CA, USA). A specialized 3 mL ASE cell was utilized for this study. The ribbon kelp was mixed with Empore Filter Aid 400 high density glass beads from Varian (Harbor City, CA, USA). The glass beads were used as a support medium and prevented the ASE cell from clogging due to the ribbon kelp expanding.The ASE parameters were: 30z70 MeOH±H2O, 500 psi, ambient temperature, 1 min heat step, 1 min static step, 30% Øush step, 1 cycle and a 120 s purge. The Zymark TurboVap LV evaporator was set to 50 �C with a nitrogen purge. The extract was next brought to dryness. The residue was then redissolved in water and treated with a maxi clean C18 cartridge (900 mg) from Alltech Associates, Inc. (DeerÆeld, IL, USA). The C18 puriÆed sample was used in all further testing. A summary of the ASE instrumental conditions can be found in Table 1.Chromatography ICP-MS and ESI-MS-MS The ion chromatography was completed utilizing a Dionex Gradient pump (Model GPM2), which utilizes a pre- and postcolumn six-way valve injector. The post-column injection introduces the marker peak and the pre-column injection is used for chromatographic separation. Three different chromatographic separations were utilized. The Ærst chromatographic separation conditions consist of an ION 120 column from Interaction Chromatography (San Jose, CA, USA) with a 40 mM (NH4)2CO3, pH 10.5 mobile phase.The Øow rate was 1 mL min21 with a 100 mL injection loop. This chromatographic separation was used with direct nebulization ICP-MS detection. The second chromatographic separation conditions involve a PRP-X100 column from Hamilton (Reno, NV, USA) and a 20 mM (NH4)2CO3, pH 9.0 mobile phase. The Øow rate was 1 mL min21 with a 100 mL (ICP-MS and ESI-MS) or a 360 mL (ESI-MS-MS) injection loop.This chromatographic separation was used with direct nebulization ICP-MS and ESIMS- MS detection. The third chromatographic separation used in the hydride research incorporates the Hamilton PRP-X100 column with a 14 mM (NH4)2HPO4±14 mM HNO3, pH 6.0, mobile phase. The Øow rate was 1 mL min21 with a 50 mL injection loop. A summary of the chromatographic conditions can be found in Table 1. Direct nebulization and membrane hydride ICP-MS detection The ICP-MS used for direct nebulization was a Plasma Quad 3 from VG Elemental (Franklin, MA, USA).The Øow rates for the plasma, auxiliary and nebulizer were 13.0 L min21, 0.80 L min21 and 0.68 L min21, respectively, with a forward power of 1350 W. Data collection was completed using single ion monitoring of m/z 75. The hydride generation ICP-MS instrument was a Hewlett- Packard (Avondale, PA, USA) 4500 series. The membrane hydride generation system has been described previously.18 This system has been modiÆed to include the on-line postcolumn photo-oxidation process to allow for the detection of highly derivatized arsenicals.The on-line photo-reactor PHRED was purchased from Aura Industries, Inc. (State Island, NY, USA). The reactor compartment was equipped with an 8 W UV lamp (254 nm) and a polished stainless steel support plate with holes at the bottom, which allowed the TeØon tubing reaction coil to extend in or out of the reactor. For better irradiation efÆciency, the original Øat-shaped PHRED knitted reaction coil (designed to Æt on the bottom support plate under the UV lamp) was replaced with a 5 m thin-wall microbore PTFE tubing (id 0.56 mm, wall 0.02 mm, Cole-Parmer Instrument Company, Vernon Hills, IL, USA) reactor, which was braided around the UV lamp.The IC efØuent was mixed with 2% K2S2O8 solution at a three-way PTFE manifold mixer and passed through the reaction coil under UV irradiation. A cooling device for the UV lamp was not provided with PHRED, and for this reason a warm up period of 15±20 min was used to ensure that thermal equilibrium was achieved.ESI-MS-MS The Finnigan MAT TSQ 700 (San Jose, CA, USA) triple quadrupole mass spectrometer, equipped with an API I interface, was utilized in the ESI-MS and ESI-MS-MS mode. The instrument was initially tuned for ESI using a myoglobin± MRFA mixture. The electrospray needle was held at 5 kV and was operated in the positive ion mode.The heated capillary (275 �C), the nitrogen sheath gas (80 psi) and the nitrogen auxiliary gas (35) were optimized using arsenobetaine infused at 1 mL min21 in 20 mM (NH4)2CO3. The heated capillary and manifold temperatures were 275 and 100 �C, respectively. In MS experiments, the instrument was scanned from 130 to 550 u s21. The MS-MS experiments were conducted using a collision energy of 30 eV and an argon pressure of 1 mTorr. The IC-ESI-MS-MS experiment was performed as follows: during retention time windows of 0±6 min, 6±10 min and 10± 16 min, Q1 was set to pass m/z 329, 483 and 393, respectively, and Q3 was scanned at 75±331, 75±485 and 75±395 u s21, respectively.A summary of these instrumental conditions can be found in Table 1. 1830 J. Anal. At. Spectrom., 1999, 14, 1829±1834Results and discussion Edmonds and Francesconi46 characterized 2 arsenosugars extracted from brown kelp using IR and NMR in 1981. Corr and Larsen41 characterized three arsenosugars via ESI-MS-MS using direct infusion for sample introduction.These three arsenosugars are retained on the ION 12047 and PRP-X10047 anion exchange columns using typical mobile phases [(NH4)2CO3] and pHs (wpH 9). Given these chromatographic conditions, the arsenosugars can potentially co-elute with As(III), DMA and AsB producing a false positive or misidentiÆcation. Fig. 1 demonstrates this co-elution problem utilizing the ION 120 column, 40 mM (NH4)2CO3 at pH 10.5.These conditions are standard conditions used in our laboratory for arsenic speciation in seafood extracts. Fig. 1 contains two chromatograms collected using these separation conditions and direct nebulization ICP-MS detection. The Ærst chromatogram (top, broken line, y axis on right of graph) is an injection of a kelp extract which contained three arsenosugars (combined 6.1 ng injected, based on a total arsenic measurement). See Table 2 for arsenical structures.The second chromatogram (bottom, solid line, y axis on left of graph) is a standard injection of 1.0 ng of each of AsB, DMA and As(III). These two chromatograms clearly indicate the potential for misidentiÆcation of arsenosugar 482 (482 is based on molecular mass, see IC-ESI-MS section and Table 2) as DMA and arsenosugar 328 as AsB. Similar chromatograms are obtained if a PRP-X100 column is used.47 Le et al.48 have reported similar co-elution and potential misidentiÆcation effects (on anion exchange columns) in human urine produced by the ingestion of arsenosugars from seafoods.Le et al.44 utilized ICP-MS and atomic Øuorescence as detectors and relied on elution times for identiÆcation. In order to minimize the potential for misidentiÆcation, a separation using a PRP-X100 column and 20 mM (NH4)2CO3 mobile phase at pH 9.0 was developed. This produces a near baseline separation of all known anionic arsenicals in 30 min. This separation allowed the retention times obtained for the three arsenosugars using IC-ICP-MS to be used to verify the retention times of the [MzH]z species found utilizing IC-ESI-MS.The relative abundance (based on chromatographic peak areas) of the three arsenosugars in the kelp extract determined by IC-ICP-MS was 5.0% (arsenosugar 328, m/z 329), 11.0% (arsenosugar 482, m/z 483) and 84.0% (arsenosugar 392, m/z 393). This distribution was calculated using the extraction conditions in Table 1 and an extraction efÆciency of 55% (i.e., the kelp after extraction contained 45% of the available arsenic based on a total arsenic digestion). IC-ESI-MS and MS-MS of arsenosugars from ribbon kelp Electrospray ionization coupled with IC-MS and IC-MS-MS was utilized to determine the identity of the three unknown arsenic peaks (from a ribbon kelp extract) observed in Fig. 1.The chromatographic conditions were optimized (as mentioned above) to produce near baseline resolution of all arsenicals.The separation and detection conditions used in Fig. 2 and 3(a±c) are listed in Table 1. Fig. 2 is a chromatogram of the ribbon kelp extract obtained by positive ion IC-ESI-MS. The Ægure has threlapping traces of m/z 329 ([MzH]z, arsenosugar 328), m/z 483 ([MzH]z, arsenosugar 482) and m/z 393 ([MzH]z, arsenosugar 392). Except for arsenosugar 392, the signal at these masses is a minor component of the total ion current. The retention times for the three unknown peaks via IC-ESI-MS are within 0, 4 and 7% (respectively) of the retention times obtained via IC-ICP-MS.This slight shift in retention times for late eluting peaks may be produced by the relatively weak mobile phase in combination with the 1 : 10 dilution factor used in the IC-ICP-MS analysis. The net effect is that the matrix anions in the IC-ESI-MS analysis are depleting the available sites (relative to IC-ICP-MS analysis) on the anion PRP-X100, thereby producing shorter retention times. From the ESI mass spectra obtained at these retention times, it was determined that the unknown arsenic peaks had molecular weights of 328 (arsenosugar 328), 482 (arsenosugar 482), and 392 (arsenosugar 392).These molecular weights matched molecular weights published by Corr and Larsen41 for the arsenosugars. This molecular weight match in combination with the conÆrmation of the presence of an arsenic heteroatom (via IC-ICP-MS) made the three arsenosugars a logical choice for tentative identiÆcation.Collisionally activated decomposition (CAD) was performed on the [MzH]z of each unknown arsenic peak to further Table 1 Summary of experimental conditions Chromatography– PRP-X100 column Direct analysis: 20 mM (NH4)2CO3, pH 9.0 Hydride analysis: 14 mM (NH4)2HPO4±14 mM HNO3, pH 6.0 ION 120 column Direct analysis: 40 mM (NH4)2CO3, pH 10.5 Flow rate and injection volume ICP-MS and ESI-MS: 1 mL min21 and 100 mL Hydride analysis ICP-MS: 1 mL min21 and 50 mL ESI-MS/MS analysis: 1 mL min21 and 360 mL Accelerated solvent extraction– Solvent: 30z70 (w/w) MeOH±H2O Pressure: 500 psi Temperature: ambient Flush percentage: 30% Cell size: 3 mL Static time: 1 min Purge time: 120 s Hydride generation– NaBH4: 1.5% (w/w) in 0.1 M NaOH HCl: 35% (w/w) Potassium persulfate: 2% (w/w) Membrane: expanded polytetraØuoroethylene microporous tubing Electrospray MS and electrospray MS-MS– Finnigan MAT TSQ 700 Auxiliary Øow: 35 nitrogen (arbitrary units) Sheath Øow: 80 psi nitrogen Capillary temperature: 275 �C Electrospray needle potential: 5 kV Fig. 1 Potential for misidentiÆcation of arsenicals using IC-ICP-MS detection. Chromatographic conditions: ION 120 column; isocratic 40 mM (NH4)2CO3, pH 10.5, 1 mL min 21. Solid line, 1 ng of each arsenical; broken line, 6.1 ng arsenosugars based on total As measurement. Numbers in parentheses refer to molecular weights established by ESI-MS. J. Anal. At. Spectrom., 1999, 14, 1829±1834 1831conÆrm that the unknown peaks were arsenosugars.To obtain adequate sensitivity in the MS-MS mode it was necessary to inject 360 mL of an undiluted extract (22.1 ng). The MS-MS mass spectra obtained on the eluting peaks are shown in Fig. 3(a±c). The MS-MS spectra of the three unknown peaks (arsenosugar 328; arsenosugar 482; arsenosugar 392) are similar to the MS-MS spectra of the arsenosugars published by Corr and Larsen41, given the differences in the instrumentation used in the experiments.All three MS-MS spectra contain m/z 237, 195 and 97, which are fragments of the base dimethylarsinylriboside, common to all the arsenosugars. While m/z 97 could be OSO3 z in arsenosugar 392, this would not explain its presence in arsenosugar 328 or arsenosugar 482. Thus, the structure shown in Fig. 3(a±c) involving the pentose moiety common to all the sugars is one possible assignment for m/z 97 in all three arsenosugars. This assignment is in agreement with Pergantis et al.39 In the case of arsenosugar 392, some of the m/z 97 signal in the MS-MS spectrum may be due to OSO3 z.The MS-MS spectrum of arsenosugar 482 shows additional fragments at m/z 465 (loss of water), 391 and 329, which are fragments of the phosphate functional group. The MS-MS spectrum of arsenosugar 392 does not contain the daughter ions at m/z 149, 167 and 279 reported by Corr and Larsen.41 One possibility for this difference is that Corr and Larsen41 noted large phthalate contamination in their arsenosugars, which dominated the MS spectra.If this contamination was extremely severe, it is Table 2 Arsenical chemical structures Fig. 2 Electrospray IC-MS mass chromatogram of arsenicals extracted from ribbon kelp. Chromatographic conditions: PRP-X100 column, isocratic 20 mM (NH4)2CO3, pH~9.0, 1 mL min21. Broken line, m/z 329; dotted line, m/z 483; solid line, m/z 393. Fig. 3 MS-MS spectra of three arsenosugars. (a) MS-MS of As (328); (b) MS-MS of As (482); (c) MS-MS of As (392). 1832 J. Anal. At. Spectrom., 1999, 14, 1829±1834possible that the daughter ions at m/z 149, 167 and 279 observed during direct infusion were produced by dioctylphthalate (nominal MW 390) via carry over. The MS-MS spectra shown in Fig. 3(a±c) provide additional data which indicate that the unknown chromatographic peaks are arsenosugars rather than the typical arsenicals found in the environment. These IC-ESI-MS and IC-ESI-MS-MS spectra, coupled with the retention time veriÆcation with ICP-MS, give credence to the presence of the three arsenicals but without arsenosugar standards this conÆrmation is tentative. Ion chromatography membrane hydride generation ICP-MS The arsenicals commonly used to assess exposure are inorganic arsenic [As(III) and As(V)], MMA and DMA.Therefore, an arsenic exposure assessment methodology should provide interference free detection of these species and minimize the potential for false positives from other arsenicals.This added degree of detector selectivity can be achieved by using a membrane hydride ICP-MS methodology without a postcolumn photo-oxidation step. A summary of these chromatographic and hydride generation conditions can be found in Table 1. The highly substituted arsenicals (arsenobetaine, etc.) are not hydride active without photo-oxidation.44,45 This allows the highly substituted arsenicals to chromatographically co-elute with As(III), As(V), MMA or DMA without producing a false positive.This selectivity is demonstrated in Fig. 4(a±b). Fig. 4(a) contains two chromatograms collected with the hydride generation system operating with a post-column online photo-oxidation step prior to detection. The separation conditions are dramatically different from those used in Fig. 1± 3. The column is a PRP-X100 with a 14 mM (NH4)2HPO4± 14 mM HNO3, pH 6.0, mobile phase. This mobile phase is used because it does not produce a gaseous species (i.e., CO2 from an ammonium carbonate mobile phase) within the hydride generation reaction and for this reason produces a more reproducible/steady baseline.The Ærst chromatogram in Fig. 4(a) (indicated by the solid line) is an injection of 50 pg of AsB, As(III), MMA and 100 pg of DMA and As(V). The arsenobetaine peak marked AsB/STD is a post-column injection. This post-column injection of AsB indicates the on-line photo-oxidation step is functioning.Similar selectivity has been demonstrated by Le et al.44,48 using on-line microwave HGAAS. This chromatogram indicates a clean separation of the four arsenicals in approximately 9 min. The second chromatogram (indicated by a broken line) in Fig. 4(a) is the separation of the ribbon kelp extract (0.6 ng arsenosugar injected, based on a total measurement) achieved using the exact same chromatographic/hydride condition. All three arsenosugars are hydride active after being subjected to the on-line photo-oxidation process.In addition, the elution order is the same as in Fig. 1 and 2 and all three species still maintain a retention characteristic on the PRP-X100 column at a pH of 6.0. The combination of both chromatograms clearly indicates that the three arsenosugars do not produce a direct chromatographic overlap but do complicate the identiÆcation process based on retention time. Fig. 4(b) contains two chromatograms in which the on-line photo-oxidation step is not utilized. The Ærst chromatogram ndicated by a solid line) is a standard mix [100 pg As(V), DMA and 50 pg of AsB, As(III) and MMA].This clearly indicates the excellent sensitivity achievable using a hydride ICP-MS system. Note: The post-column injection of AsB does not produce a response. This indicates the photo-oxidation step is inoperable. The second chromatogram (indicated by a broken line) is a 50 mL injection of the ribbon kelp extract (12.3 ng g21 arsenosugar based on a total measurement) without photo-oxidation.The Øat baseline indicates that the arsenosugars in the ribbon kelp extract shown in Fig. 4(a) are not hydride active without some type of oxidative step prior to detection. Le et al.44 have demonstrated this via microwave digestion of arsenosugars in urine samples. The highly substituted arsenicals, e.g., AsB, arsenocholine (AsC), etc., are normally not hydride active without photo-oxidation. Arsenosugars produce non-volatile hydrides which are not detectable.Therefore, by carefully monitoring experimental conditions, highly substituted arsenicals could be co-eluted with As(III), As(V), MMA or DMA and detected without producing a false positive. These data provide additional evidence to indicate the presence of arsenosugars and that these arsenosugars [characterized by IC-ESI-MS-MS in Fig. 3(a±c)] are the only detected arsenicals in the ribbon kelp. In addition, the hydride generation mode of detection without the photooxidation step signiÆcantly simpliÆes the chromatograms while photo-oxidation provides the analyst with the Øexibility of detecting the arsenosugars for exposure source information. The above data clearly indicate the selectivity differences between IC-ESI-MS, IC-ICP-MS and IC-hydride-ICPMS.Selectivity is one aspect which is a growing requirement in arsenic speciation methodologies while instrumental sensitivity is challenged, especially in solid sample extracts.In an attempt to make a sensitivity comparison between IC-ICP-MS, IC-ESI-MS and IC-hydride-ICP-MS, a concentration for the m/z 483 peak was calculated from the relative area distribution and the total arsenic concentration in the extract. The relative area per cent of the m/z 483 peak is 11% and the total arsenic concentration in the extract is 613 ng g21, therefore the m/z 483 peak is 67 ng g21. Using 67 ng g21 of arsenic as the concentration for the m/z 482 peak and calculating a 3 sigma Fig. 4 Chromatographic separation of arsenicals using hydride generation with (a) on-line photo-oxidation. Chromatographic conditions: PRP-X100 column, isocratic 14 mM (NH4)2HPO4±14 mM HNO3, pH 6.0, 1 mL min21. Solid line, 100 pgDMAand AsV, 50 pg AsB, AsIII and MMA; broken line, 615 pg of total arsenosugars injected. Numbers in parentheses refer to molecular weights established by ESI-MS. (b) Without on-line photo-oxidation.*Dwell time is 2 s. J. Anal. At. Spectrom., 1999, 14, 1829±1834 1833detection limit based on peak height, the following detection limits were calculated. The 3 sigma detection limits were 4.5, 150 and 1.5 pg for the IC-ICP-MS, IC-ESI-MS, and IChydride- ICP-MS, respectively. It should be noted that the ICESI- MS data collection and ESI experimental parameters were not optimized for detection limits but rather were compromised to facilitate the IC separation developed for IC-ICP-MS.Conclusions The elemental selectivity of atomic spectrometric detection provides excellent sensitivities relative to IC-ESI-MS but does not provide structural information available with IC-ESI-MS and IC-ESI-MS-MS. Hydride IC-ICP-MS provides unparalleled sensitivity and increased selectivity but still does not provide a structural identiÆcation capability for unknowns. Unlike ICP-MS the total ion current chromatograms obtained from an IC-ESI-MS-MS indicate a wide variety of co-extracted organic constituents eluting from the IC.This makes the identiÆcation of species which may contain arsenic very difÆcult without the use of the elemental information obtained via IC-ICP-MS. The arsenicals are, in effect, minor constituents via IC-ESI-MS while the ICP-MS can provide the elemental information necessary to identify IC retention windows of interest for the identiÆcation of arsenosugars from the ribbon kelp extract. The IC-ESI-MS spectra clearly indicate that the eluting species have the same molecular ion as those reported in the literature while the IC-ESI-MS-MS spectra conÆrm structural similarities to those reported in the literature.Finally, the ICP-MS chromatograms indicate the presence of an arsenic heteroatom during each of the three corresponding retention windows. From this perspective and a methods development standpoint the techniques are complementary and each provide supporting structural or elemental conÆrmation.Clearly, ICP-MS elemental information is inadequate in providing the structural information needed to identify these arsenosugars; on the other hand, IC-ESI-MS and IC-ESI-MSMS as applied in this paper lack the sensitivity necessary for arsenic exposure assessment. Hydride ICP-MS does provide an added degree of selectivity, which minimizes the required chromatographic resolution while providing an analytical response for the most toxicologically relevant arsenicals.From this perspective, the IC-ESI-MS-MS structural information has allowed the arsenosugars to be identiÆed and this identiÆcation has allowed a hydride IC-ICP-MS analytical approach to be tested for false positives produced from arsenosugars. Acknowledgements The authors would like to thank Roseanne M. Lorenzana, US EPA Region 10, for her generosity in supplying us with the ribbon kelp sample utilized in this study. We would also like to recognize Douglas T. Heitkemper, US FDA, whose help through a cooperative study has been invaluable.References 1 M. M. Frey and M. A. Edwards, J. Am. Water Works Assoc., 1997, 89, 105. 2 R. W. Dabeka, A. D. McKenzie, G. M. A. Lacroix, C. Cleroux, S. Bowe, R. A. Graham, H. B. S. Conacher and P. Verdier, J. AOAC Int., 1993, 76, 14. 3 E. L. Gunderson, J. AOAC Int., 1995, 78, 910. 4 E. L. Gunderson, J. AOAC Int., 1995, 78, 1353. 5 J. S. Edmonds and K. A. Francesconi, Mar. Pollut. Bull., 1993, 26, 665. 6 S. Branch, L.Ebdon and P. O'Neill, J. Anal. At. Spectrom., 1994, 9, 33. 7 J. Alberti, R. Rubio and G. Rauret, Fresenius' J. Anal. Chem., 1995, 351, 420. 8 D. Velez, N. Ybanez and R. Montoro, J. Agric. Food Chem., 1995, 43, 1289. 9 D. Velez, N. Ybanez and R. Montoro, J. Agric. Food Chem., 1996, 44, 859. 10 T. Kaise, H. Yamauchi, T. Hirayamas and S. Fukuis, Appl. Organometall. Chem., 1988, 2, 339. 11 S. X. C. Le, W. R. Cullen and K. J. Reimer, Environ. Sci. Technol., 1994, 28, 1598. 12 W.R. Chappell and C. O. Abernathy, in Arsenic Exposure and Health, ed. W. R. Chappell, C. O. Abernathy and C. R. Cothern, Science and Technology Letters, Northwood, Middlesex, UK, 1994, ch. 2, pp. 21±29. 13 G. Lunde, J. Sci. Food Agric., 1973, 24, 1021. 14 Toxicological ProÆle for Arsenic, ATSDR/TP-88/02, prepared by Life Systems Inc. for Agency for Toxic Substances and Disease Registry U.S. Public Health Service, in collaboration with US EPA, March 1998, Oak Ridge National Laboratory, TN, USA, 1989. 15 H. Hasegawa, Y. Sohrin, M. Matsui, M. Hojo and M. Kawashima, Anal. Chem., 1994, 66, 3247. 16 S. J. Haswell, P. O'Neill and K. C. C. Bancroft, Talanta, 1985, 32, 69. 17 C. Hwang and S. Jiang, Anal. Chim. Acta, 1994, 289, 205. 18 M. L. Magnuson, J. T. Creed and C. A. Brockhoff, J. Anal. At. Spectrom., 1996, 11, 893. 19 P. Thomas and K. Sniatecki, J. Anal. At. Spectrom., 1995, 10, 615. 20 X. C. Le and M. Ma, Anal. Chem., 1998, 70, 1926. 21 M. Ma and X. C.Le, Clin. Chem., 1998, 44, 539. 22 X. Le, W. R. Cullen and K. J. Reimer, Clin. Chem., 1994, 40, 617. 23 G. K. C. Low, G. E. Batley and S. J. Buchanan, Chromatographia, 1986, 22, 292. 24 E. H. Larsen, G. Pritzi and S. H. Hansen, J. Anal. At. Spectrom., 1993, 8, 557. 25 D. Heitkemper, J. Creed, J. Caruso and F. L. Fricke, J. Anal. At. Spectrom., 1989, 4, 279. 26 G. M. Momplaisir, J. S. Blais, M. Quinteiro and W. D. Marshall, J. Agric. Food Chem., 1991, 39, 1448. 27 E. A. Crecelius, Environ. Health Perspect., 1977, 19, 147. 28 R. Cornelis and J. De Kimpe, J. Anal. At. Spectrom., 1994, 9, 945. 29 B. S. Sheppard, J. A. Caruso, D. T. Heitkemper and K. A. Wolnik, Analyst, 1992, 117, 971. 30 J. P. Buchet, J. Pauwels and R. Lauwerys, Environ. Res., 1994, 66, 44. 31 K. D. Arbinda, R. Chakraborty, M. L. Cervera and M. de la Guardia, Mikrochim. Acta, 1996, 122, 209. 32 W. C. Story, J. A. Caruso, D. T. Heitkemper and L. Perkins, J. Chromatogr. Sci., 1992, 30, 427. 33 J. Alberti, R. Rubio and G. Rauret, Fresenius' J. Anal. Chem., 1995, 351, 420. 34 D. Beauchemim, K. W. M. Siu, J. W. McLaren and S. S. Berman, J. Anal. At. Spectrom., 1989, 4, 285. 35 E. H. Larsen, G. Pritzi and S. H. Hansen, J. Anal. At. Spectrom., 1993, 8, 1075. 36 M. A. Lopez, M. M. Gomez, M. A. Palacios and C. Camara, Fresenius' J. Anal. Chem., 1993, 346, 643. 37 M. Van Holderbeke, Y. Zhao, F. Vanhaecke, L. Moens, R. Dams and P. Sandra, J. Anal. At. Spectrom., 1999, 14, 229. 38 B. Michalke and P. Schramel, Electrophoresis, 1998, 19, 2220. 39 S. A. Pergantis, K. A. Francesconi, W. Groessler and J. E. Thomas-Oates, Anal. Chem., 1997, 69, 4931. 40 K. W. M. Siu, G. J. Gardner and S. S. Berman, Rapid Commun. Mass Spectrom., 1988, 2, 69. 41 J. J. Corr and E. H. Larsen, J. Anal. At. Spectrom., 1996, 11, 1215. 42 S. A. Pergantis, W. Winnik and D. Betowski, J. Anal. At. Spectrom., 1997, 12, 531. 43 K. W. M. Siu, R. Guevremont, J. C. Y. LeBlanc, G. J. Gardner and S. S. Berman, J. Chromatogr., 1991, 554, 27. 44 X. C. Le, M. Ma and N. A. Wong, Anal. Chem., 1996, 68, 4501. 45 R. H. Atallah and D. A. Kalman, Talanta, 1991, 38, 167. 46 J. S. Edmonds and K. A. Francesconi, Nature, 1981, 289, 602. 47 P. A. Gallagher, J. W. McKiernan, X. Wei, C. A. Brockhoff, J. A. Shoemaker, J. T. Creed and J. A. Caruso, European Winter Conference on Plasma Spectrochemistry, Pau, France, January 10±15, 1999, C7. 48 X. C. Le, W. R. Cullen and K. J. Reimer, Talanta, 1994, 41, 495ss. Paper 9/06249A 1834 J. Anal. At. Spectrom., 1999, 14, 1829±1834

 



返 回