首页   按字顺浏览 期刊浏览 卷期浏览 Compact high‐voltage vacuum feedthrough
Compact high‐voltage vacuum feedthrough

 

作者: J. D. Stein,  

 

期刊: Review of Scientific Instruments  (AIP Available online 1976)
卷期: Volume 47, issue 12  

页码: 1555-1556

 

ISSN:0034-6748

 

年代: 1976

 

DOI:10.1063/1.1134549

 

出版商: AIP

 

数据来源: AIP

 

摘要:

A vacuum feedthrough has been designed at this laboratory to operate at 40 kV and 10−9Torr. It is small in size, 3.81 cm in diameter and extending 4.45 cm into the vacuum chamber. A selection of commercial connectors is available. The re‐entrant design fully shields the conductor for safety, prevention of noise pickup, and protection from environmental effects.

 