首页   按字顺浏览 期刊浏览 卷期浏览 Emittance measurements on a volume H−ion source
Emittance measurements on a volume H−ion source

 

作者: J. G. Alessi,  

 

期刊: AIP Conference Proceedings  (AIP Available online 1990)
卷期: Volume 210, issue 1  

页码: 526-533

 

ISSN:0094-243X

 

年代: 1990

 

DOI:10.1063/1.39627

 

出版商: AIP

 

数据来源: AIP

 

摘要:

A current of 30 mA has been extracted from a volume production H−source having a toroidal discharge chamber and rotational symmetry. This is a current density of 30 mA/cm2. The emittance measurement gave a normalized, 90% value of &egr;N(90%)=0.32 &pgr; mm‐mrad for a 13 mA beam. The ion temperature is estimated to be 0.57 eV for this case. For 25.5 mA, &egr;N(90%)=1.1 &pgr; mm‐mrad was measured, but the true value is most likely smaller due to a limitation in the emittance resolution.

 

点击下载:  PDF (429KB)



返 回