首页   按字顺浏览 期刊浏览 卷期浏览 Low Impedance Transmission System for Driving Cryogenic Circuits
Low Impedance Transmission System for Driving Cryogenic Circuits

 

作者: David J. Dumin,  

 

期刊: Review of Scientific Instruments  (AIP Available online 1962)
卷期: Volume 33, issue 7  

页码: 715-720

 

ISSN:0034-6748

 

年代: 1962

 

DOI:10.1063/1.1717941

 

出版商: AIP

 

数据来源: AIP

 

摘要:

The possible advantages and disadvantages of driving cryotron circuits with a low impedance transmission system instead of a high impedance system are discussed. It is shown that although losses are higher in a low impedance cable, a reduction in the signal coupled between cables in a cryotron system is possible when low impedance cable is used. Two low impedance generators are described. These generators have a maximum frequency between 500 kc and 1 Mc. The rise time is less than 2 nsec and can be improved when the generators are packaged in strip line module form. Pulse amplitude is about 1.5 A. Pulse width is variable by use of a delay cable.

 