The measurement of large pulse voltages at 200 Mc/s
作者:
A.L.Cullen,
期刊:
Journal of the Institution of Electrical Engineers - Part IIIA: Radiolocation
(IET Available online 1946)
卷期:
Volume 93,
issue 8
页码: 1311-1314
年代: 1946
DOI:10.1049/ji-3a-1.1946.0217
出版商: IEE
数据来源: IET
摘要:
A method of measuring pulse voltages up to 10 kV at a frequency of 200 Mc/s is described. The voltage to be measured is applied to one end of a three-quarter wavelength line, short circuited at the other end. The sinusoidal distribution of voltage thus set up is used as a potential divider, the voltage at a small, known distance from the voltage node being measured with a valve peak-voltmeter. A method of eliminating the input capacitance of the valve voltmeter is described. Possible sources of error are discussed and their magnitude is estimated.
点击下载:
PDF
(511KB)
返 回