首页   按字顺浏览 期刊浏览 卷期浏览 Heat Transfer in a Scraped-Wall, Continuous Unit
Heat Transfer in a Scraped-Wall, Continuous Unit

 

作者: V. RAMDAS,   V. W. UHL,   M. W. OSBORNE,   J. R. ORTT,  

 

期刊: Heat Transfer Engineering  (Taylor Available online 1980)
卷期: Volume 1, issue 4  

页码: 38-46

 

ISSN:0145-7632

 

年代: 1980

 

DOI:10.1080/01457638008939567

 

出版商: Taylor & Francis Group

 

数据来源: Taylor

 

摘要:

The effect of the use of scrapers on the film heat transfer coefficient was investigated. Experimental runs were conducted in liquid-full, continuous-flow heat exchangers of commercial size, with a 6-in. ID and 6-ft length. Three test fluids were used: two petroleum lube fractions and corn syrup. Flow rates were varied from 0.8 to 5.8 gpm and the scraper speed from 0.5 to 25 rpm. The data collected were utilized in developing a design correlation in the laminar regime (Rer < 150). The correlation obtained for heating and cooling was Nu = 57 Ref0.059Rer0.113Pr0.063Visr−0.018, for 0.0016 < Ref < 9.23 and 0.0164 < Rer< 68.65.

 

点击下载:  PDF (647KB)



返 回