Dosimetry of small radiation fields for 10‐MV x rays
作者:
Pavel V. Houdek,
John M. VanBuren,
Juan V. Fayos,
期刊:
Medical Physics
(WILEY Available online 1998)
卷期:
Volume 10,
issue 3
页码: 333-336
ISSN:0094-2405
年代: 1998
DOI:10.1118/1.595262
出版商: American Association of Physicists in Medicine
数据来源: WILEY
摘要:
Dosimetry for 10‐MV x rays has been extended to radiation fields smaller than 4×4 cm which may be suitable for radiation therapy of small lesions, e.g., intracranial tumors, benign or malignant. Special consideration in this study was given to (i) the variation of dose with field size (collimator and phantom scatter), (ii) the central axis percentage depth doses, and (iii) the moving‐beam therapy dose distribution. We conclude that simple dosimetric techniques can provide adequate physics background for stereotaxic radiosurgery with small radiation fields and high‐energy x rays.