Electrical machine core imperfection detection
作者:
C.Rickson,
期刊:
IEE Proceedings B (Electric Power Applications)
(IET Available online 1986)
卷期:
Volume 133,
issue 3
页码: 190-195
年代: 1986
DOI:10.1049/ip-b.1986.0026
出版商: IEE
数据来源: IET
摘要:
The paper describes the development of a core imperfection monitoring and detection system which eliminates the need for a high-voltage high-current excitation winding. The system is based on an electromagnetic testing technique. The paper reports a number of tests conducted in the United Kingdom and USA and gives comparisons of results made with the conventional ring flux test method and the new method. Accuracy of fault location and ease of implementation are discussed.