An analytical expression was developed to define the incipient drawdown of a thermocline into a submerged intake equipped with a circular cover. The critical discharge at the incipient drawdown was expressed in terms of dimensionless variables defining the thermal structure of the surrounding water body and the geometric properties of the intake structure.The relationship was verified by laboratory experiments and by field data.