Effect of Myocardial Fiber Direction on Epicardial Potentials

 

作者: Bruno Taccardi,   Emilio Macchi,   Robert Lux,   Philip Ershler,   Santa Spaggiari,   Silvana Baruffi,   Yonild Vyhmeister,  

 

期刊: Circulation  (OVID Available online 1994)
卷期: Volume 90, issue 6  

页码: 3076-3090

 

ISSN:0009-7322

 

年代: 1994

 

出版商: OVID

 

关键词: potentials;electrocardiography;electric stimulation;anisotropy;mapping

 

数据来源: OVID

 

摘要:

BackgroundUnderstanding the relations between the architecture of myocardial fibers, the spread of excitation, and the associated ECG signals is necessary for addressing the forward problem of electrocardiography, that is, predicting intracardiac and extracardiac ECGs from known intracardiac activity. So far, these relations have been studied experimentally only in small myocardial areas. In this study, we tested the hypothesis that potential distributions measured over extensive epicardial regions during paced beats reflect the direction of superficial and intramural fibers through which excitation is spreading in both the initial and later stages of ventricular excitation. We also tried to establish whether the features of the epicardial potential distribution that correlate with fiber direction vary as a function of pacing site, intramural pacing depth, and time elapsed after the stimulus. An additional purpose was to compare measured epicardial potentials with recently published numerical simulations depicting the three-dimensional spread of excitation in the heart muscle and the associated potential fields.Methods and ResultsThe hearts of 18 mongrel dogs were exposed and 182 to 744 unipolar electrograms were recorded from epicardial electrode arrays (2.3 × 3.0 to 6.5 × 6.5 cm). Hearts were paced at various intramural depths through an intramural needle. The overall number of pacing sites in 18 dogs was 241. Epicardial potential distributions, electrographic waveforms, and excitation time maps were displayed, and fiber directions in the ventricular wall underlying the electrodes were determined histologically. During the early stages of ventricular excitation, the position of the epicardial maxima and minima revealed the orientation of myocardial fibers near the pacing site in all cases of epicardial and intramural pacing and in 60% of cases of endocardial or subendocardial pacing. During later stages of propagation, the rotation and expansion of the positive areas correlated with the helical spread of excitation through intramurally rotating fibers. Marked asymmetry of potential patterns probably reflected epicardial-endocardial obliqueness of intramural fibers. Multiple maxima appeared in the expanding positive areas.ConclusionsFor 93% of pacing sites, results verified our hypothesis that epicardial potential patterns elicited by ventricular pacing reflect the direction of fibers through which excitation is spreading during both the initial and later stages of propagation. Epicardial potential distributions provided information on the site of origin and subsequent helical spread of excitation in an epicardial-endocardial, endocardial-epicardial, or double direction. Results were in agreement with previously published numerical simulations except for the asymmetry and fragmentation of the positive areas.

 

点击下载:  PDF (3495KB)



返 回