This paper discusses the origin and concepts of kinetic model equations and standard specifications used to size a biological treatment system (size of aeration tank and aeration requirements). They are shown to yield very similar calculations for a domestic type of waste water, but may yield much different values if the waste water behaves differently than domestic waste. The kinetic model approach, therefore, should be considered more flexible and superior in its ability to yield appropriate design values.