Determinants of the limits of agreement between the sphygmomanometer and the SpaceLabs 90207 device for blood pressure measurement in healthy volunteers and insulin‐dependent diabetic patients

 

作者: Frans van Ittersum,   Renate Wijering,   Jan Lambert,   Ab Donker,   Coen Stehouwer,  

 

期刊: Journal of Hypertension  (OVID Available online 1998)
卷期: Volume 16, issue 8  

页码: 1125-1130

 

ISSN:0263-6352

 

年代: 1998

 

出版商: OVID

 

关键词: limits of agreement;SpaceLabs 90207 device;sphygmomanometer;insulin-dependent diabetes

 

数据来源: OVID

 

摘要:

ObjectiveTo compare the limits of agreement between the SpaceLabs 90207 oscillometric blood pressure measurement device and the sphygmomanometer for patients with insulin-dependent diabetes mellitus (IDDM) versus healthy control subjects.DesignA retrospective analysis of six simultaneous blood pressure measurements in 106 IDDM patients aged 32.6 ± 12.0 years (mean ± SD) and 92 healthy control subjects aged 27.1 ± 8.9 years with the SpaceLabs device and a sphygmomanometer.ResultsFor both groups, overestimation of the systolic blood pressure occurred with the SpaceLabs device, being more severe for the IDDM group (1.7 mmHg more overestimation,P= 0.009). Mean arterial blood pressure was underestimated for the control group and overestimated for the IDDM group (2.7 mmHg underestimation and 0.8 mmHg overestimation, respectively). Diastolic blood pressures for both groups were underestimated by use of the SpaceLabs device, but less severely so for the IDDM group (4.2 mmHg,P< 0.0001 less underestimation). Multiple regression analysis revealed that these differences were mainly due to the presence of diabetes. Other determinants of these limits of agreement were age (for control group subjects) and duration of diabetes (for IDDM group patients).ConclusionLimits of agreement between the SpaceLabs 90207 device and the sphygmomanometer differ between IDDM patients and healthy controls. These limits are influenced by the presence of diabetes, age and duration of diabetes. Available protocols for the evaluation of automated blood pressure measurement devices of the British Hypertension Society and the Association for the Advancement of Medical Instrumentation do not consider limits of agreement in subpopulations such as diabetic patients. Therefore, we recommend that tests for the limits of agreement of blood pressure measurement devices for subgroups should be added to these protocols.

 

点击下载:  PDF (297KB)



返 回