首页   按字顺浏览 期刊浏览 卷期浏览 Mass Balance Analysis of Ozone in Conventional Bubble Contactors
Mass Balance Analysis of Ozone in Conventional Bubble Contactors

 

作者: M. Roustan,   J.P. Duguet,   B. Brette,   E. Brodard,   J. Mallevialle,  

 

期刊: Ozone: Science & Engineering  (Taylor Available online 1987)
卷期: Volume 9, issue 3  

页码: 289-298

 

ISSN:0191-9512

 

年代: 1987

 

DOI:10.1080/01919518708552342

 

出版商: Taylor & Francis Group

 

关键词: Ozone;Mass Transfer;Ozone Contactor Design;Mass Balance;Bubble Diffuser Contactors

 

数据来源: Taylor

 

摘要:

Ozone transfer into potable water was studied in a commercial scale contactor. Ozone mass balances have been calculated to determine ozone utilization in the contactor. Gas and liquid flowrates, as well as inlet ozone concentrations in the gas were varied. From these data it was possible to determine the mass transfer coefficient, the ozone consumption and the transfer efficiency. Procedures for calculating the design of contactors and the optimal operating conditions are proposed.

 