Relations Entre Le Test Immuoenzymatique “Elisa” Et La Réaction De Hémagglutination Passive Dans L'évaluation De L'antitoxine Tétanique Humaine -étude Expériment Ale Et Biométrique
作者:
Maria-Magdalena Bǎutǎ,
Rodica Mihǎiilescu,
Maria Mateescu,
Cecilia Stolan,
期刊:
Analytical Letters
(Taylor Available online 1984)
卷期:
Volume 17,
issue 16
页码: 1877-1892
ISSN:0003-2719
年代: 1984
DOI:10.1080/00032718408077190
出版商: Taylor & Francis Group
关键词: test immunoenzymatique ELISA;hémagglutination passive;tétanos(titre anticorps;seuil de protection);standardisation des méthodes
数据来源: Taylor
摘要:
A biometrical study carried out on 50 sera, concerning relationships between ELISA 31-13 passive hemagglutination (PHA), both previously standardized against the neutralization test (NT) for the evaluation of antitetanic imunity level, is described, The statistical analysis of intermethods regression and of variance allowed for the estimation of the immunological proteation limit established at a 0.3 IU/ml value (upper confidence limit, p ⩽0.05) in terns of PHA, corresponding to 0.015 IU/ml in terms of ELISA at the same probability level, The correlation coefficient was 0.94, The precision of ELISA was significantly higher in comparison with those of NT and PHA The reasons for a selective choice of the proper type of test in various circumstances are discussed.