SHORT COMMUNICATION
作者:
R. ZHENG,
K.N.C. BRAY,
B. ROGG,
期刊:
Combustion Science and Technology
(Taylor Available online 1997)
卷期:
Volume 126,
issue 1-6
页码: 389-401
ISSN:0010-2202
年代: 1997
DOI:10.1080/00102209708935683
出版商: Taylor & Francis Group
数据来源: Taylor
摘要:
The response of laminar premixed fuel-lean methane-air counterflow flames to the combined effects of stretch and cooling by a fine spray of water and NaCl-water as well as surfactant-water solution is studied experimentally. Results show that flame extinction is promoted both by increased flame stretch and by a higher concentration of liquid. An unexpected finding is that at a given concentration an NaCl-water solution is significantly more effective than pure water in causing flame extinction. On the other hand, at the concentration studied, results from a spray of water containing a surfactant ∥Synperonic PE/L62) are indistinguishable from those with pure water.