Differentiation of Asymptomatic Patients from Symptomatic Patients by the Slope of the Forced Vergence Fixation Disparity Curve
作者:
BRUCE TEITELBAUM,
PETER MICCA,
GREGORY JONES,
MICHAEL THURN,
TOMMIE LEE,
期刊:
American Journal of Optometry and Physiological Optics
(OVID Available online 1985)
卷期:
Volume 62,
issue 4
页码: 282-286
ISSN:0093-7002
年代: 1985
出版商: OVID
关键词: disparometer;fixation disparity;slope
数据来源: OVID
摘要:
Eighty-nine optometry students were divided into an asymptomatic group and a symptomatic group on the basis of a case history. A forced vergence fixation disparity (FD) curve was generated for each subject using a Disparometer (Vision Analysis, Columbus, Ohio). Slopes were calculated for each curve. In addition, each curve was labeled steep or flat based on a previously determined cutoff point of −0.96 min/Δ (Sheedy, 1980). Steep curves did not correlate well with symptomatic patients, whereas flat curves did not correlate well with asymptomatic patients. An independent t-test found no significant difference between the two groups.