Pulsed Eddy‐Current NDE at Iowa State University — Recent Progress and Results
作者:
M. J. Johnson,
J. R. Bowler,
F. Azeem,
期刊:
AIP Conference Proceedings
(AIP Available online 1903)
卷期:
Volume 657,
issue 1
页码: 390-396
ISSN:0094-243X
年代: 1903
DOI:10.1063/1.1570162
出版商: AIP
数据来源: AIP
摘要:
Iowa State University’s pulsed eddy‐current system has been redesigned to be smaller, more sturdy and easier to install and operate. Improvements have been made to the electronic circuits, the computer interface, the enclosure design and to the software. Changes have resulted in a much more user‐friendly system that it portable and can be installed quickly and easily in the field. As part of an evaluation of the new system, bond‐thickness measurements on specimens supplied by Cessna were carried out. Results were found to be in good agreement with those obtained by direct measurement. Additional experiments were carried out on corrosion specimens from SAIC Ultra Image Inc. Using data from these specimens a calibration‐based approach to flaw quantification is demonstrated. © 2003 American Institute of Physics