Monotonic transient response
作者:
O.P.D.Cutteridge,
期刊:
Proceedings of the IEE - Part IV: Institution Monographs
(IET Available online 1954)
卷期:
Volume 101,
issue 6
页码: 46-54
年代: 1954
DOI:10.1049/pi-4.1954.0005
出版商: IEE
数据来源: IET
摘要:
The paper considers the restrictions which must be placed on the poles and zeros of a system function of a linear system with lumped constants in order that the response of the system to a step-function drive should be monotonic. Necessary and sufficient restrictions are derived for a system function (driving-function/response-function) containing up to three zeros, and these are interpreted as permissible pole-zero positions on the complex plane for the one- and two-zero cases and also for a number of instances in the three-zero case.The paper concludes with a method of obtaining sufficient conditions for monotonic response in the case of more complicated system functions from the results given in the paper.
点击下载:
PDF
(1022KB)
返 回