首页   按字顺浏览 期刊浏览 卷期浏览 Theoretical Evaluation of an Oscillating Mass Flow in the Modified Moore Variometer Con...
Theoretical Evaluation of an Oscillating Mass Flow in the Modified Moore Variometer Configuration

 

作者: Uri Fehr,   Carl Gazley,  

 

期刊: Review of Scientific Instruments  (AIP Available online 1967)
卷期: Volume 38, issue 10  

页码: 1502-1507

 

ISSN:0034-6748

 

年代: 1967

 

DOI:10.1063/1.1720571

 

出版商: AIP

 

数据来源: AIP

 

摘要:

The behavior of an oscillating mass flow through a series of capillary tubing ending in a large reservoir, and representing the fluid mechanics system of the modified Moore variometer used by UCLA as an infrasound detector system, is analyzed both theoretically and experimentally. A comparison of the theoretical and experimental results enables an understanding of the operation of the sensor and suggests future improvements.

 

点击下载:  PDF (327KB)



返 回