首页   按字顺浏览 期刊浏览 卷期浏览 Evaluation op the dc electrical environment in proximity to VDTS
Evaluation op the dc electrical environment in proximity to VDTS

 

作者: T. Dan Bracken,   WilliamH. Bailey,   JonathanM. Charry,  

 

期刊: Journal of Environmental Science and Health . Part A: Environmental Science and Engineering  (Taylor Available online 1985)
卷期: Volume 20, issue 7  

页码: 745-780

 

ISSN:0360-1226

 

年代: 1985

 

DOI:10.1080/10934528509375257

 

出版商: Taylor & Francis Group

 

数据来源: Taylor

 

摘要:

Two VDTs were tested to determine their impact on the DC electrical environment. Characteristics of the DC environment were measured — ion concentration, ion current density and DC electric field. Measures of particulate levels, temperature and humidity were included since these factors are known to influence the DC environment. Ion concentrations, especially negative ion concentrations, varied as a function of distance from the VDTs, with the lowest values observed in the immediate vicinity of the VDTs for both models tested. This effect was slight and within the range of expected indoor values for ion concentrations. DC electric fields were generally found to be higher during VDT operation compared to controls, although they were within the same order of magnitude as commonly experienced fields due to charges on materials (e.g. clothing, carpet) indoors. Particulate levels were not observed to be altered by VDT operation.

 

点击下载:  PDF (970KB)