首页   按字顺浏览 期刊浏览 卷期浏览 Influence of Dacron Tissue Thickness on the Performance of the Pintucci Biointegrable K...
Influence of Dacron Tissue Thickness on the Performance of the Pintucci Biointegrable KeratoprosthesisAn In Vitro and In Vivo Study

 

作者: Stefano Pintucci,   Roberto Perilli,   Giuseppe Formisano,   Salvatore Caiazza,  

 

期刊: Cornea  (OVID Available online 2001)
卷期: Volume 20, issue 6  

页码: 647-650

 

ISSN:0277-3740

 

年代: 2001

 

出版商: OVID

 

关键词: Dacron;Keratoprosthesis;Light microscopy;Scanning electron microscopy

 

数据来源: OVID

 

摘要:

Purpose.In 1979 Pintucci developed a biointegrable keratoprosthesis with polymethylmethacrylate optical cylinder integrated with a Dacron tissue-colonizable supporting element to avoid the complications caused by the interaction between the haptic element and the eye. The purpose of this article is to compare the colonization of three Dacron fabrics (thicknesses of 0.25 mm, 0.6 mm, and 1.4 mm) in vitro and in vivo to optimize the device performance.Methods.In vitro three different Dacron fabrics were cultured for 3 days with 3.5 × 105human fetal lung fibroblasts and observed with a scanning electron microscope. In vivo three different Dacron fabrics were implanted on the sclera near the superior rectus insertion in the right eye of six albino rabbits and were observed after 4 days with light and scanning electron microscopy.Results.In the in vitro experiments, the cells were preserved and their structure was found to be normal. The 0.25-mm thick fabric was coated only on the surface, and the other fabrics were colonized in three dimensions. In the in vivo experiments, the 0.25-mm thick fabric appeared coated only on its surface. The other fabrics were three-dimensionally colonized and the Dacron filaments appeared embedded in neovascularized connective tissue with minimal foreign body reaction. The 1.4-mm thick colonized fabric showed a substantial loss of pliability.Conclusion.Given that the 0.25-mm thick fabric was coated only by connective tissue, that the 0.6-mm and 1.4-mm thick fabrics were perfectly colonized, and that the 1.4-mm thick fabrics showed a substantial loss of pliability, the 0.6-mm thick fabric haptic part of the Pintucci keratoprosthesis is preferred. For 19 years, the 0.6-mm Dacron fabric Pintucci keratoprosthesis was implanted in 159 eyes with good results, overcoming the apparently inseparable difficulties represented by mechanical anchorage and biointegrability of a keratoprosthesis.

 

点击下载:  PDF (706KB)



返 回