Ozonation at Wiggins Water Purification Works, Durban, South Africa
作者:
G.E. Rencken,
期刊:
Ozone: Science & Engineering
(Taylor Available online 1994)
卷期:
Volume 16,
issue 3
页码: 247-260
ISSN:0191-9512
年代: 1994
DOI:10.1080/01919519408552501
出版商: Taylor & Francis Group
关键词: Ozone;Post-Ozonation;Disinfection;Ozone Plant Problems;Algal Flocculation Impairment Caused By Ozonation;Drinking Water Treatment;Wiggins Waterworks;Color Removal;Chlorine Poisoning of Off–Gas Destruct Catalyst;Disinfection;Viral Inactivation;Taste
数据来源: Taylor
摘要:
The post-ozone plant at Wiggins waterworks was commissioned during 1984. The main objective of the post–ozone plant was to ensure proper disinfection, including the elimination of viruses, whenever raw water for the works was pumped from the polluted lower Umgeni River. The main problems experienced with the post–ozone plant were poor ozone transfer efficiency in the contact tank and poisoning of the catalyst in the thermal-catalytic destructor.
点击下载:
PDF (559KB)
返 回