首页   按字顺浏览 期刊浏览 卷期浏览 Microacoustic Interferometer Using 30‐Mc Pulses
Microacoustic Interferometer Using 30‐Mc Pulses

 

作者: R. A. McConnell,   W. F. Mruk,  

 

期刊: The Journal of the Acoustical Society of America  (AIP Available online 1955)
卷期: Volume 27, issue 4  

页码: 672-676

 

ISSN:0001-4966

 

年代: 1955

 

DOI:10.1121/1.1907989

 

出版商: Acoustical Society of America

 

数据来源: AIP

 

摘要:

In the described instrument ten‐microsecond, 30‐Mc carrier pulses reflected from a resonant layer allow a theoretical precision of 0.1 percent in making velocity determinations while using less than 0.1 cc of test liquid. By the same technique, ultrasonic absorption can be measured in highly dissipative liquids using layers about 0.1 mm thick. Water velocities observed at 30 Mc are presented along with values by others in the range of 0° to 93°C.V = 1554−0.0305(68.4−T)2is proposed as the best empirical parabola to accommodate the available data, and an additional cubic correction formula is suggested.

 

点击下载:  PDF (596KB)



返 回