An improved DC potential drop system for crack length measurement
作者:
Chow‐Shing Shin,
Wen‐Han Huang,
Hong‐Yie Chen,
期刊:
Journal of the Chinese Institute of Engineers
(Taylor Available online 1993)
卷期:
Volume 16,
issue 1
页码: 29-40
ISSN:0253-3839
年代: 1993
DOI:10.1080/02533839.1993.9677474
出版商: Taylor & Francis Group
关键词: DC potential drop;crack length measurement;DCPD calibration;Pipe;compact tension specimen;switch‐off DCPD;reversing DCPD
数据来源: Taylor
摘要:
DC potential drop has long been used for automatic crack length monitoring, yet details about its set‐up, causes of errors, precautions to achieve optimum performance and actual long term stability and accuracy under practical conditions have seldom been documented in detail. A DCPD system was established and details about its long term performance under varying loading and temperature parameters were evaluated. Necessary precautions to reduce error and improve accuracy are discussed. The system resolution is 0.003mm when applied to a compact tension specimen. The long term system accuracy achieved was ± 0.012mm. Two approaches for improvement were also attempted. It was found that the switch‐off approach at least doubled the accuracy and the reversing polarity approach raised the accuracy by nearly ten times. The improved system has been applied to a large pipe fracture specimen. The resulting empirical calibration data agrees closely with independently obtained finite element results.
点击下载:
PDF (929KB)
返 回