首页   按字顺浏览 期刊浏览 卷期浏览 Influence of the pre‐rinse on the efficiency of circulation cleaning milking machines
Influence of the pre‐rinse on the efficiency of circulation cleaning milking machines

 

作者: R J RUNNALLS,  

 

期刊: International Journal of Dairy Technology  (WILEY Available online 1988)
卷期: Volume 41, issue 1  

页码: 14-16

 

ISSN:1364-727X

 

年代: 1988

 

DOI:10.1111/j.1471-0307.1988.tb00576.x

 

出版商: Blackwell Publishing Ltd

 

数据来源: WILEY

 

摘要:

The effect of volume and temperature of pre‐rinse water on the cleaning efficiency of five circulation cleaned recorder milking machines was investigated. A hot (>75 °C) pre‐rinse gave the lowest bacteriological rinse total colony counts. As the rinse count differences were small, the least expensive cold water pre‐rinse is considered satisfactory for most farms. A pre‐rinse volume of 16 litres per unit removed more residual milk than eight litres per unit but gave no significant difference in rinse counts. For most plants 8–10 litres per unit is considered a satisfactory pre

 

点击下载:  PDF (1134KB)