Absolute response and noise equivalent power of cyclotron resonance‐assisted InSb detectors at submillimeter wavelengths

 

作者: Elliott R. Brown,   M. J. Wengler,   T. G. Phillips,  

 

期刊: Journal of Applied Physics  (AIP Available online 1985)
卷期: Volume 58, issue 5  

页码: 2051-2059

 

ISSN:0021-8979

 

年代: 1985

 

DOI:10.1063/1.335989

 

出版商: AIP

 

数据来源: AIP

 

摘要:

Spectra are presented of the responsivity and noise equivalent power (NEP) of liquid‐helium‐cooled InSb detectors as a function of magnetic field in the range 20–110 cm−1. The measurements are all made using a Fourier transform spectrometer with thermal sources. The results show a discernable peak in the detector response at the conduction electron cyclotron resonance (CCR) frequency for magnetic fields as low as 3 kG. The magnitude of responsivity at the resonance peaks is roughly constant with magnetic field and is comparable to the low‐frequency hot‐electron bolometer response. The NEP at the peaks is found to be comparable to the best long wavelength results previously reported. For example, we measure NEP=4.5×10−13W/Hz1/2at 4.2 K, 6 kG, and 40 cm−1. The InSb CCR will provide a much improved detector for laboratory spectroscopy, as compared with hot electron bolometers, in the 20–100 cm−1range.

 