首页   按字顺浏览 期刊浏览 卷期浏览 Radioimmunoscintigraphy of recurrent, metastatic, or occult colorectal cancer with tech...
Radioimmunoscintigraphy of recurrent, metastatic, or occult colorectal cancer with technetium Tc 99m 88BV59H21‐2V67‐66 (HumaSPECT®‐Tc), a totally human monoclonal antibodyPatient management benefit from a phase III multicenter study

 

作者: Bruce Wolff,   John Bolton,   Richard Baum,   Alain Chetanneau,   Alain Pecking,   Aldo Serafini,   Alan Fischman,   Herbert Hoover,   Jerry Klein,   Gordon Wynant,   Ramaswamy Subramanian,   Diana Goroff,   Michael Hanna,  

 

期刊: Diseases of the Colon & Rectum  (OVID Available online 1998)
卷期: Volume 41, issue 8  

页码: 953-962

 

ISSN:0012-3706

 

年代: 1998

 

出版商: OVID

 

关键词: Human monoclonal antibody;Monoclonal antibody imaging;Technetium;Colorectal cancer;88BV59;HumaSPECT®‐Tc

 

数据来源: OVID

 

摘要:

PURPOSE:The study contained herein was undertaken to evaluate the accuracy of radiolabeled human monoclonal antibody, 88BV59H21‐2V67‐66 (88BV59 or HumaSPECT®‐Tc), in predicting disease resectability in presurgical subjects with recurrent, metastatic, or occult colorectal carcinoma.METHODS:A total of 219 patients with disease visualized on computed tomographic scan (recurrent or metastatic disease) or with negative or equivocal computed tomographic scan and rising carcinoembryonic antigen serum levels (occult group) received technetium Tc 99m‐labeled 88BV59 intravenously. Planar and single photon emission computed tomographic images were obtained 14 to 20 hours postinfusion, before surgery. The ability of computed tomographic and HumaSPECT®‐Tc imaging to define the extent of disease and to predict resectability was evaluated based on surgical and histopathologic results.RESULTS:In patients with recurrent or metastatic disease (170 evaluable patients), the accuracy of predicting non‐resectability of disease was significantly greater (P<0.001) for HumaSPECT®‐Tc than for computed tomography (60vs.29 percent). Computed tomography understaged 41 percent of patients believed to have resectable disease compared with 27 percent for HumaSPECT®‐Tc (P<0.001). In occult disease patients (29 computed tomographic and 28 HumaSPECT®‐Tc evaluable patients), the overall accuracy of predicting resectability/nonresectability was 68 percent for HumaSPECT®‐Tc compared with 24 percent for computed tomography. Administration of HumaSPECT®‐Tc had no effect on monoclonal antibody‐basedin vitrodiagnostic assays. Only a single patient demonstrated an anti‐antibody response (90 ng/ml) at nine weeks postinfusion.CONCLUSION:HumaSPECT®‐Tc was more accurate than computed tomography in determining disease resectability in patients with metastatic, recurrent, or occult cancer. The addition of HumaSPECT®‐Tc imaging can play a significant role in patient management decisions.

 

点击下载:  PDF (1552KB)



返 回