首页   按字顺浏览 期刊浏览 卷期浏览 Measurement of Lung Microvascular Pressure in the Intact Anesthetized Rabbit by the Mic...
Measurement of Lung Microvascular Pressure in the Intact Anesthetized Rabbit by the Micropuncture Technique

 

作者: Sunita Bhattacharya,   Matthew Glucksberg,   Jahar Bhattacharya,  

 

期刊: Circulation Research  (OVID Available online 1989)
卷期: Volume 64, issue 1  

页码: 167-172

 

ISSN:0009-7330

 

年代: 1989

 

出版商: OVID

 

关键词: intact lung;lung microvascular pressure;lung micropuncture;pulmonary circulation

 

数据来源: OVID

 

摘要:

We have developed a micropuncture technique for the measurement of microvascular pressure in the intact lung of rabbit. We anesthetized 16 rabbits (halothane, 0.8%) and mechanically ventilated them through a tracheotomy. Then, we exposed the right lung by rib resection over the right anterior chest. We measured pulmonary artery, left a trial, and systemic pressures by direct catheterization and cardiac output by the thermodilution technique. For micropuncture, we stabilized the lung on a shelf and stopped ventilation for 3-4 minutes at an airway pressure of 7 cm H2O. We injected pancuronium intravenously to paralyze the diaphragm and intercostal muscles. Of the total pulmonary vascular pressure drop, 52% occurred in the microvascular segment between arterioles and venules of 20 μm diameter, 28% occurred in the arterial segment, and 20% occurred in the venous segment. We conclude that in the intact lung of rabbit, the major pressure drop occurs in the microvascular segment.

 

点击下载:  PDF (866KB)



返 回