Effects of Electromagnetic Field on Bone Healing Around Commercially Pure Titanium Surface: Histologic and Mechanical Study in Rabbits

 

作者: Edmur,   Buzzá Jamil,   Shibli Roberto,   Barbeiro José,  

 

期刊: Implant Dentistry  (OVID Available online 2003)
卷期: Volume 12, issue 2  

页码: 182-187

 

ISSN:1056-6163

 

年代: 2003

 

出版商: OVID

 

关键词: dental implants;electrical stimulation;mechanical tests;osseointegration

 

数据来源: OVID

 

摘要:

PurposeThe purpose of this pilot study was to evaluate the histologic and mechanical healing process in dental implants under the action of pulsed electromagnetic field (PEMF).Materials and MethodsForty-eight commercially pure implant fixtures were implanted in tibiae metaphysis of 12 New Zealand white rabbits divided into experimental (PEMF) and control groups. A PEMF with pulse width of 85 &mgr;s and a pulse frequency of 20 Mc was applied for 30 minutes per day. The animals were killed 21 and 42 days after implantation. The mechanical tests were performed in all animals and bone biopsies were prepared for decalcified sections analysis.ResultsMechanical tests did not show significant differences between the groups (P> 0.05); however, statistically significant differences were observed over time (P< 0.0001). Similar histologic features were achieved for both groups.ConclusionsThese results suggest that PEMF stimulation does not improve the bone-healing process around commercially pure dental implants.

 