An equipment for measuring the attenuation of low-loss waveguide transmission lines
作者:
D.G.Keith-Walker,
期刊:
Proceedings of the IEE - Part B: Electronic and Communication Engineering
(IET Available online 1959)
卷期:
Volume 106,
issue 13S
页码: 71-74
年代: 1959
DOI:10.1049/pi-b-2.1959.0013
出版商: IEE
数据来源: IET
摘要:
Some methods of measuring the attenuation in waveguides are discussed, and the particular difficulties involved in the determination of low attenuations are outlined. The measurement of the Q-factor of a resonant line appears to be the most satisfactory method for short specimen lengths of waveguide, and the paper deals chiefly with the special equipment required for the measurement of Q-factors of the order of 106. The frequency stability required for the measurement of the very small frequency changes involved is very considerable, and the apparatus described ensures that frequency instability of the oscillator will not affect this measurement. Frequency differences are measured by a frequency discriminator using a waveguide delay line, the output of the discriminator being capable of accurate absolute calibration.The effects of cavity losses other than wall losses are theoretically investigated, since their magnitude influences the minimum length of cavity that can be used.