首页   按字顺浏览 期刊浏览 卷期浏览 Assessment of a domestic heat pump 2: Component and frosting analysis
Assessment of a domestic heat pump 2: Component and frosting analysis

 

作者: I. R. Cox‐Smith,   C. G. Carrington,  

 

期刊: International Journal of Energy Research  (WILEY Available online 1990)
卷期: Volume 14, issue 1  

页码: 27-37

 

ISSN:0363-907X

 

年代: 1990

 

DOI:10.1002/er.4440140105

 

出版商: Wiley Subscription Services, Inc., A Wiley Company

 

关键词: Heat pump;Frosting;Component performance

 

数据来源: WILEY

 

摘要:

AbstractThe performance of the heat exchangers of an unsophisticated air‐air heat pump are examined with particular emphasis on the evaporator frosting characteristics. The data relate to an operating domestic heat pump in Dunedin. Evaporator frosting reduces the seasonal COP by only a small amount (less than 1.7%) in this example but the defrost rate is shown to be very sensitive to small changes in the evaporator capacity. Thus frost formation generally has an important influence on the evaporator optimization calculation. The effectiveness of the expansion valve and of the defrost thermostat is also analysed, and particular opportunities for improving the system are identifie

 

点击下载:  PDF (669KB)