Assessment of a domestic heat pump 2: Component and frosting analysis
作者:
I. R. Cox‐Smith,
C. G. Carrington,
期刊:
International Journal of Energy Research
(WILEY Available online 1990)
卷期:
Volume 14,
issue 1
页码: 27-37
ISSN:0363-907X
年代: 1990
DOI:10.1002/er.4440140105
出版商: Wiley Subscription Services, Inc., A Wiley Company
关键词: Heat pump;Frosting;Component performance
数据来源: WILEY
摘要:
AbstractThe performance of the heat exchangers of an unsophisticated air‐air heat pump are examined with particular emphasis on the evaporator frosting characteristics. The data relate to an operating domestic heat pump in Dunedin. Evaporator frosting reduces the seasonal COP by only a small amount (less than 1.7%) in this example but the defrost rate is shown to be very sensitive to small changes in the evaporator capacity. Thus frost formation generally has an important influence on the evaporator optimization calculation. The effectiveness of the expansion valve and of the defrost thermostat is also analysed, and particular opportunities for improving the system are identifie