Simple apparatus for the liquefaction of neon directly into a research Dewar
作者:
T. L. Francavilla,
R. J. Soulen,
J. H. Claassen,
期刊:
Review of Scientific Instruments
(AIP Available online 1993)
卷期:
Volume 64,
issue 7
页码: 2023-2026
ISSN:0034-6748
年代: 1993
DOI:10.1063/1.1143993
出版商: AIP
数据来源: AIP
摘要:
A simple apparatus for liquefying neon is described for use in experiments that require a stable thermal environment at 27 K. This apparatus makes use of a closed‐cycle refrigerator attached to an insulated cold finger inserted into a conventional stainless steel Dewar to liquefy a quantity of neon gas stored previously in a tank. The system is inexpensive and easy to use. Furthermore, the neon is recovered for subsequent reuse upon completion of the experiment. Starting with a Dewar holding a small coil that had not been precooled, and using a refrigerator with rated cooling capacity of 15 W at 26 K, approximately 0.5lof liquid neon was condensed into the Dewar in ∼4 h. The apparatus has been used to measure the critical currents of highTcoxide tape coils both with and without the application of an external magnetic field.
点击下载:
PDF
(527KB)