首页   按字顺浏览 期刊浏览 卷期浏览 Osmotic Biosensors. How to Use a Characean Internode for Measuring the Alcohol Content ...
Osmotic Biosensors. How to Use a Characean Internode for Measuring the Alcohol Content of Beer

 

作者: M. Rüdinger,   P. Hierling,   E. Steudle,  

 

期刊: Botanica Acta  (WILEY Available online 1992)
卷期: Volume 105, issue 1  

页码: 3-12

 

ISSN:0932-8629

 

年代: 1992

 

DOI:10.1111/j.1438-8677.1992.tb00260.x

 

出版商: Blackwell Publishing Ltd

 

关键词: Alcohol;biosensor;Characeae;osmotic cell;solute transport;water relations

 

数据来源: WILEY

 

摘要:

AbstractIsolated internodes ofChara corallinaandNitella flexilishave been used to determine the concentration of one passively permeating solute in the presence of non‐permeating solutes. The technique was based on the fact that the shape of the peaks of the biphasic responses of cell turgor (as measured in a conventional way using the cell pressure probe) depended on the concentration and composition of the solution and on the permeability and reflection coefficients of the solutes. Peak sizes were proportional to the concentration of the permeating solute applied to the cell. Thus, using the selective properties of the cell membrane as the sensing element and changes of turgor pressure as the physical signal, plant cells have been used as a new type of biosensor based on osmotic principles. Upon applying osmotic solutions, the responses of cell turgor (P) exactly followed the P(t) curves predicted from the theory based on the linear force/flow relations of irreversible thermodynamics. The complete agreement between theory and experiment was demonstrated by comparing measured curves with those obtained by either numerically solving the differential equations for volume (water) and solute flow or by using an explicit solution of the equations. The explicit solution neglected the solvent drag which was shown to be negligible to a very good approximation. Different kinds of local beers (regular and de‐alcoholized) were used as test solutions to apply the system for measuring concentrations of ethanol. The results showed a very good agreement between alcohol concentrations measured by the sensor technique and those obtained from conventional techniques (enzymatic determination using alcohol dehydrogenase or from measurement of the density and refraction index of beer). However, with beer as the test solution, the characean internodes did show irreversible changes of the transport properties of the membranes leading to a shift in the responses when cells were treated for longer than 1 h with diluted beer. The accuracy and sensitivity of the osmotic biosensor technique as well as its possible applications are discus

 

点击下载:  PDF (978KB)



返 回