首页   按字顺浏览 期刊浏览 卷期浏览 Development of an intense negative hydrogen ion source with an external magnetic filter
Development of an intense negative hydrogen ion source with an external magnetic filter

 

作者: Y. Takeiri,   A. Ando,   O. Kaneko,   Y. Oka,   K. Tsumori,   R. Akiyama,   E. Asano,   T. Kawamoto,   T. Kuroda,   M. Tanaka,   H. Kawakami,  

 

期刊: Review of Scientific Instruments  (AIP Available online 1995)
卷期: Volume 66, issue 3  

页码: 2541-2546

 

ISSN:0034-6748

 

年代: 1995

 

DOI:10.1063/1.1145655

 

出版商: AIP

 

数据来源: AIP

 

摘要:

An intense negative hydrogen ion source has been developed, which has a strong external magnetic filter field in the wide area of 35 cm×62 cm produced by a pair of permanent magnet rows located at 35.4 cm separation. The filter strength is 70 G in the center and the line‐integrated filter strength is 850 G cm, which keeps the low electron temperature in the extraction region. Strong cusp magnetic field, 1.8 kG on the chamber surface, is generated for improvement of the plasma confinement. These resulted in the high arc efficiency at the low operational gas pressure. 16.2 A of H−ion current with the energy of 47 keV was obtained at the arc efficiency of 0.1 A/kW at the gas pressure of 3.8 mTorr in the cesium‐mode operation. The magnetic field in the extraction gap is also strong, 450 G, for the electron suppression. The ratio of the extraction current to the negative ion current was less than 2.2 at the gas pressure of 3 mTorr. The two‐stage acceleration was tested, and 13.6 A of H−ion beam was accelerated to 125 keV. ©1995 American Institute of Physics.

 

点击下载:  PDF (748KB)



返 回