首页   按字顺浏览 期刊浏览 卷期浏览 Relationship between the Calibration Tone and Speech Volume Unit (VU) Levels ...
Relationship between the Calibration Tone and Speech Volume Unit (VU) Levels for Some Commercially Available Test Tapes

 

作者: Bradly,   Edgerton Randall,   Beattie Larry,  

 

期刊: Ear and Hearing  (OVID Available online 1982)
卷期: Volume 3, issue 5  

页码: 280-283

 

ISSN:0196-0202

 

年代: 1982

 

出版商: OVID

 

数据来源: OVID

 

摘要:

The relationship between the calibration tone and speech volume unit (VU) levels for nine commercially recorded speech tests was studied. Two procedures were used. In procedure 1, experienced clinicians reported observations of four different audiometer VU meters responding to six commercially available speech tests. Differences in magnitude estimates among judges were usually about 1 dB or less. Peak VU level deviations from the zeroed calibration tone were within k1.5 VU except for the Fulton Lewis Jr. recording, which varied by about −4.8 VU. In procedure 2, a video system was used to record precisely VU meter responses to clinical speech materials. Differences between the calibration tones and speech levels were similar to those obtained using multiple observers. Statistically significant (p 5 0.01) differences were found between the speech levels of the commercial test recordings.

 

点击下载:  PDF (311KB)



返 回