Diagnosis and Differentiation of HIV‐1 and HIV‐2 Infection by Two Rapid Assays in Nigeria
作者:
Richard Kline,
Abinbola Dada,
William Blattner,
Thomas Quinn,
期刊:
Journal of Acquired Immune Deficiency Syndromes
(OVID Available online 1994)
卷期:
Volume 7,
issue 6
页码: 623-626
ISSN:0894-9255
年代: 1994
出版商: OVID
关键词: HIV-1;HIV-2;Nigeria;Rapid assays;Testing strategy
数据来源: OVID
摘要:
We evaluated the reliability, sensitivity, and specificity of two rapid assays, TestPack HIV-1/HIV-2 and Genie HIV-1/HIV-2, in Lagos, Nigeria. An alternative algorithm to EIA and Western blot was then examined with the TestPack HIV-1/HIV-2 used as the screening test and the Genie HIV-1/HIV-2 used as the supplemental test to differentiate HIV-1 and HIV-2 infection. In all, 845 prostitutes were evaluated for HIV-1 and HIV-2 infection using one of the two rapid tests and compared to EIA and Western blot results. Of these 845 cases, 437 samples were analyzed by both assays. Overall, 109 (12.7%) prostitutes were antibody positive for HIV-1, 13 (1.5%) for HIV-2, and six (0.7%) were dually reactive for both HIV-1 and HIV-2. Compared to Western blot, the Genie HIV-1/HIV-2 had a slightly higher sensitivity and specificity (98.4% and 99.7%) than the TestPack HIV-1/HIV-2 (97.6% and 99.3%). The alternative algorithm using both rapid assays had a sensitivity of 96.9% and a specificity of 99.9%. The Genie HIV-1/HIV-2 correctly identified 104 of 108 HIV-1 positive sera, 12 of 13 HIV-2 positive sera, and all six dually positive sera. Both assays performed well in the field. They required
点击下载:
PDF
(304KB)