Absorbed dose comparison: positron emitters11C,13N, and15O versus gamma‐ray emitters
作者:
Paul A. Feller,
Vincent J. Sodd,
Hiroshi Nishiyama,
期刊:
Medical Physics
(WILEY Available online 1998)
卷期:
Volume 6,
issue 3
页码: 221-223
ISSN:0094-2405
年代: 1998
DOI:10.1118/1.594567
出版商: American Association of Physicists in Medicine
数据来源: WILEY
摘要:
Absorbed doses were calculated or taken from the literature for various compounds of11C,13N, and15O, and compared to those of presently used gamma‐ray‐emitting nuclear medicine radiopharmaceuticals. As a rule of thumb, the doses per millicurie of the injectable positron‐emitting compounds are of the same order of magnitude as the dose per millicurie of99mTc compounds. The absorbed doses from the injectable positron emitters are nearly one or more orders of magnitude lower on a per millicurie basis than those from the other injectable gamma emitters that were investigated.