首页   按字顺浏览 期刊浏览 卷期浏览 Compact pulsed molecular beam system for real‐time reactive scattering from soli...
Compact pulsed molecular beam system for real‐time reactive scattering from solid surfaces

 

作者: Benjamin N. Eldridge,   Ming L. Yu,  

 

期刊: Review of Scientific Instruments  (AIP Available online 1987)
卷期: Volume 58, issue 6  

页码: 1014-1026

 

ISSN:0034-6748

 

年代: 1987

 

DOI:10.1063/1.1139602

 

出版商: AIP

 

数据来源: AIP

 

摘要:

We describe a compact system providing the capability of striking a sample surface with a short pulse of reactive gas in an UHV environment and monitoring the evolution of ensuing volatile reaction products. A 300‐Hz rotating disk chopper synchronized with a pulsed valve produces molecular beam pulses of 12‐&mgr;s FWHM at the chopper position. Only one stage of differential pumping separates the pulsed valve chamber from the target chamber with the latter under UHV conditions. The source of the molecular beam, comprised of the chambers containing the pulsed valve and the rotating disk chopper, occupies less than one square meter of floor space. Beam characterization is accomplished by the use of two UHV compatible fast ion gauges located in the target chamber. Reaction products are monitored with microsecond resolution via a differentially pumped quadrupole mass spectrometer located at right angles to the beam.

 

点击下载:  PDF (1410KB)