Boron-10 Concentration Measurements Using the Solid-State Nuclear Track Detector CR-39 and Automatic Image Analysis
作者:
BlueThomas E.,
Courtney RobertsT.,
BarthRolf F.,
TalnagiJoseph W.,
AlamFazlul,
期刊:
Nuclear Technology
(Taylor Available online 1987)
卷期:
Volume 77,
issue 2
页码: 220-226
ISSN:0029-5450
年代: 1987
DOI:10.13182/NT87-A33986
出版商: Taylor&Francis
数据来源: Taylor
摘要:
Calibration curves are determined for measuring the concentration of10B in the blood of rats using an autoradiographic procedure, with the polycarbonate solid-state nuclear track detector CR-39 and an image analysis system for automatic track counting. The calibration curves indicate that for the etch procedure used, the nitrogen concentration in the blood is an important interfering input for10B concentration measurements. By discriminating against small tracks, the sensitivity to the blood nitrogen concentration can be reduced to the point that a variation in the nitrogen weight fraction of 0.01 gN/g blood causes a variation in the predicted10B concentration of 0.3µg10B/ml blood.